POPULACE
Basler AVC63-4 / AVC63-4D Analog Generator Voltage Regulator
Model: AVC63-4
Basler AVC63-4 analog voltage regulator for brushless generators. Verify the 190–240 Vac input/sensing range, field resistance and adjustment layout for AVC63-4 versus AVC63-4D before replacement.
| Place of Origin | Fujian, China |
|---|---|
| Brand Name | POPULACE |
| Model Number | AVC63-4 |
| MOQ | 1 pc |
| Lead time | 2-3 days after payment (in stock), 3-7 days for production batches |
Applications
- Standby and prime diesel generator sets fitted with Basler alternators in telecom, data-centre and hospital backup power
- Commercial and industrial gensets requiring stable output voltage under varying load
- Alternator rewinds and rebuilds where the original AVR is obsolete or damaged
Product Description
Generator Automatic Voltage Regulator Basler AVR AVC63-4
General Features
![]() | Generator Automatic Voltage Regulator Basler AVR AVC63-4 The AVC63-4 / AVC63-4D instruction manual specifies a 190–240 Vac single-phase power and sensing input, 50/60 Hz, ±10%; see the manual for the separate 171–264 Vac voltage adjustment range. The supplied Revision F manual covers both AVC63-4 and AVC63-4D. Their adjustment potentiometers are accessed from different locations; verify the exact model before installation. |
![]() | Features * Voltage regulation < +/-1% *Soft start voltage ramping *Sensing voltage loss protection *190–240 Vac single-phase power/sensing input (see AVC63-4 / AVC63-4D Revision F manual) *Under frequency roll off protection *With under frequency LED indicator |
| Product Name | Diesel Generator Set Spare Part AVR AVC63-4 | |
| Sensing/Power input | Voltage | 190-240Vac |
| Frequency | 50/60 Hz jumper selectable | |
| Output | Voltage | 63 Vdc at 240 Vac power input |
| Current | Continuous 4A | |
There are no reviews yet.
Be the first to review “Basler AVC63-4 / AVC63-4D Analog Generator Voltage Regulator”
Your email address will not be published. Required fields are marked *
Related Products
Compatible generator parts & matching system accessories.
Technical Guides & Troubleshooting
Engineering diagnostics, terminal wiring diagrams, and parts replacement procedures.
Generator AVR Not Producing Voltage: 5 Causes and How to Test Them
A generator that runs but produces no power is most often an excitation or AVR problem. Here are the five causes we see most in the field, the multimeter check for each, and when the regulator itself needs replacing.
Read Guide → Engineering GuideGenerator Rotating Rectifier Diode Testing: How to Test Forward & Reverse Diodes with a Multimeter
Comprehensive guide to testing generator rotating rectifier assemblies (RSK1001, RSK2001, RSK5001, SSAYEC432). Learn how to diagnose shorted diodes, verify surge varistors, and replace rectifiers.
Read Guide →FAQ
The manual lists 190–240 Vac, single-phase, 50/60 Hz, ±10% for the power and sensing input, common with the AC power input. It separately lists a 171–264 Vac voltage adjustment range. Check the specific generator circuit before installation.
The manual covers both models. Their adjustment potentiometers are in different locations: AVC63-4 controls are accessed on the terminals/components side, while AVC63-4D controls are accessed through the front panel. Confirm the label and control layout before ordering.
The specified DC resistance range is 15–100 Ω. Check the exciter-field data against the correct manual before connecting a replacement regulator.
The manual lists 4 Adc at 63 Vdc (252 W) maximum continuous output and 7 Adc at 100 Vdc (700 W) one-minute forcing with 240 Vac power input. These are controller ratings, not a guarantee of system compatibility.
A Basler AVC63-4 / AVC63-4D instruction manual (Revision F) was supplied for this product mapping. Ask support to confirm the exact model-specific document and revision before installation; do not substitute the 4D adjustment layout for AVC63-4.
Send the controller nameplate/model, generator voltage and frequency, exciter-field resistance and a description or photo of the adjustment-control layout. Confirm wiring against the unit-specific manual before energizing.
20 Years Experience for Genset Parts
POPULACE has 20 years of experience supplying generator parts worldwide — reliable, OEM-compatible, and built for continuous operation.
Get a Quote