Model: DKG105

Datakom DKG105 AMF controller with programmable mains/generator limits, timers and relay configuration. Verify the 72 × 72 mm panel format, supply wiring and protection requirements against the DKG105 user manual.

Place of OriginFujian, China
Brand NamePOPULACE
Model NumberDKG105
Overall Size78 × 78 × 50 mm
Panel cut-out68 × 68 mm minimum
DC supply12 V / 24 V battery systems
Mains frequency50/60 Hz
Alternator frequency range0–100 Hz
Output terminal current rating10 A RMS per terminal (manual rating)

Applications

  • Open and enclosed Datakom-based generator sets needing automatic start/stop, protection and load management
  • Mains-failure standby systems in commercial buildings and industrial plants
  • Retrofit or replacement of failed Datakom modules on service fleets

Product Description

Datakom DKG105 Automatic Mains Failure Controller

The DKG105 monitors mains and generator conditions and can control generator start/stop and changeover functions. Its product and user manuals describe programmable timers, thresholds and relay configuration.

  • Supply: 12 V or 24 V battery system
  • Alternator frequency range: 0–100 Hz
  • Panel format: 72 × 72 mm; minimum cut-out: 68 × 68 mm
  • Overall dimensions: 78 × 78 × 50 mm
  • Maximum output-terminal current: 10 A RMS per terminal (manual rating)

The user manual states the unit is not fused and requires external fuse protection. Disconnect power before wiring and follow the model-specific user manual and local electrical regulations.

There are no reviews yet.

Be the first to review “Datakom DKG105 Automatic Mains Failure Generator Controller”

Your email address will not be published. Required fields are marked *

☆☆☆☆☆

FAQ

The product and user manuals describe an automatic mains-failure controller that monitors mains and generator conditions and controls generator start/stop and changeover functions. It has programmable timers, threshold levels and relay configuration.

The manual lists a standard 72 × 72 mm panel format, with a minimum mounting opening of 68 × 68 mm. Confirm the cut-out and mounting details from the unit manual before replacement.

The user manual states operation on 12 V and 24 V battery systems. The product manual lists 10 A RMS maximum current per output terminal. Follow the manual's wiring and protection instructions.

The user manual states the unit is not fused and calls for external fuses, including 6 A fuse protection as described in the manual. Disconnect power before wiring and follow applicable national wiring regulations.

A DKG105 product manual and user manual were supplied for this page mapping, but a verified public download file is not currently attached to this page. Contact support to confirm the correct revision and availability.

Provide the DKG105 nameplate, control-panel cut-out, battery voltage, mains/generator phase arrangement and terminal wiring information. Check the exact unit manual before connecting inputs or outputs.

20 Years Experience for Genset Parts

POPULACE has 20 years of experience supplying generator parts worldwide — reliable, OEM-compatible, and built for continuous operation.

Get a Quote